Off Grid Solar Inverter with charger
SP6000-SW

HYBRID solar INVERTER with charger
SP1200-11000-SW
SP1200/2400/3600-SR

Hybrid / Off-Grid solar Inverter with AVR and charger
SP4000-AVR

High-Efficiency Hybrid / Off-Grid solar Inverter with charger
SP1000-5000 Efecto

True Hybrid Solar Inverter (on grid+off grid)
SP3000 Premium

All in one silent generator with AC utility and Solar charging
EP1200/2400/3600-SR


Solar Pumping System
Three Phase AC solar pumping inverter
DC Solar pumping inverter

Simulate sinewave Solar Inverter with charger
SP300Junior/SP600Junior

true sinewave inverter
INS-700/INS-1000

simulated sinewave inverter
IN-150S

Solar Charger PWM (Light control)
SC-10LC/SC-20LC/SC-30LC

Solar Charger PWM
SC-45/SC-60


Solar Charger MPPT
SC-50 MPPT / SC-80 MPPT /
SC-80X MPPT

Solar Charger MPPT
SC-10 MPPT/SC-30 MPPT

Solar Charger PWM (IP67)
SC-05SM /SC-10SM /
SC-15SM / SC-20SM

SOLAR MODULE
OM6PV230

SOLAR LIGHT SYSTEM
MSS-10


Solar Power System
MSS-20 Super


solar power bank (MPPT)
12W Green Energy Kit

solar lantern
SP1
SP2


Solar Toys
Solar Carbon Fiber Car

OFF-GRID INVERTER
SP6000-SW

The OPTI-Solar OFF-GRID INVERTER, una versátil solución todo en uno, proporciona una potencia limpia de salida sinusoidal verdadera perfecta combinada con una corriente de carga de batería multifase que se puede seleccionar. El OFF-GRID INVERTER es adecuado para cualquier tipo de aplicación como, por ejemplo, aparatos de aire acondicionado o cualquier otro aparato doméstico, y su cargador inteligente carga automáticamente cualquier tipo de batería sin el riesgo de sobrecarga. Además, su diseño compacto y modular facilita y abarata la instalación. Este producto de alta calidad ofrece la mejor relación precio/rendimiento de la industria.

CARACTERÍSTICAS

* Base de diseño con varios microprocesadores
* Compatible con carga lineal y no lineal
* Cargador más robusto que admite baterías de 600 AH y más
* Funcionamiento de 24 horas en el inversor
* Panel controlable y extraíble con pantalla LCD
* Parámetro que se puede definir por adelantado
* Función de inicio de CC y de autodiagnóstico automático
* Diseño para instalación en bastidor de 19" 3u o diseño para instalación en pared
* Diseñado para trabajar en entornos duros
* Baja disipación de calor en funcionamiento a largo plazo
* THD inferior al 3%
* AC/DC Priority Switchable CPU

 

APLICACIONES

Aplicación Industrial, Residenciales, Comerciales

 

ESPECIFICACIONES

Model

SP6000-SW

Capacity

VA / Watt

6KVA / 6000W

AC Input

(from Grid)

Nominal Voltage

120Vac or 230Vac

Voltage

Range

Acceptable Voltage Range

60-135Vac or 120-270Vac

Low Voltage Transfer

60VAC ± 3% or 120VAC ± 2%

Low Voltage Return

65VAC ± 3% or 130VAC ± 2%

High Voltage Transfer

135VAC ± 3% or 270VAC ± 2%

High Voltage Return

130VAC ± 3% or 260VAC ± 2%

Frequency

50Hz or 60Hz

DC Input

(from Array)

Nominal Voltage

48V

Charger Voltage

55.2V

Solar Maximum Peak Voltage

100V

Start-up Voltage

44V

Polarity Protect

Yes

Backflow Protect

Yes

Maximum Charge Current

40A

Output

Voltage

120 Vac (110V or 115Vac re-settable via LCD panel)
230 Vac (220V or 240Vac re-settable via LCD panel)

Voltage Regulation (Battery Mode)

< 3% RMS for entire battery voltage range

Frequency Regulation

Line Mode

Synchronized to AC Main

Battery Mode

50Hz or 60Hz ± 0.1Hz

Power Factor

1.0

Waveform

Pure Sinewave

Overload Protection

 Line Mode

> 110%, then buzzer alarms and amber LED blinks continuously

 Battery Mode

110% ~ 150% for 30 sec; >150% for 200ms

Short Circuit Protection

 Line Mode

Circuit Breaker

 Battery Mode

Electronic Circuit

Transfer Time

Typical

< 8 ms.

Battery

Battery Voltage

48Vdc

Backup Time

Depends on System Load and Battery Capacity (Based on the batteries connected)

Selectable Charging Current

20A / 40A / 60A

Display 

LCD

Inverter status, I/P&O/P Voltage Frequency, Load Level,
Battery Voltage & Level, Temperature, Model

LED

Normal (Green), Warning (Amber), Fault (Red)

Audible Alarm

Battery  Mode

Beeping every 4 seconds

Low Battery

Beeping every second

Inverter Fault

Beeping Continuously

Overload

Beeping twice per second

Environment

Operation Temperature

0-40 degree C; 32-104 degree F

Relative Humidity

0-95% non-condensing

Audible Noise

Less than 55dBA (at 1M)

Physical

Net/ Gross Weight (Kg)

51.4/ 66.6

(W x H x D) (mm)

415 x 600 x 260

Accessory

RS232 or SNMP

Optional

 

 

DESCARGAS

El manual del usuario
- Descargar el manual del usuario
Catálogo
- Descargar catálogo

 

CERTIFICACIONES

CE
CE for SP Series