Off Grid Solar Inverter with charger
SP6000-SW
![]()
HYBRID solar INVERTER with charger
SP1200-11000-SW
SP1200/2400/3600-SR
![]()
Hybrid / Off-Grid solar Inverter with AVR and charger
SP4000-AVR
![]()
High-Efficiency Hybrid / Off-Grid solar Inverter with charger
SP1000-5000 Efecto
![]()
True Hybrid Solar Inverter (on grid+off grid)
SP3000 Premium
![]()
All in one silent generator with AC utility and Solar charging
EP1200/2400/3600-SR
![]()
Solar Pumping System
Three Phase AC solar pumping inverter
DC Solar pumping inverter
![]()
Simulate sinewave Solar Inverter with charger
SP300Junior/SP600Junior
![]()
true sinewave inverter
INS-700/INS-1000
![]()
simulated sinewave inverter
IN-150S
![]()
Solar Charger PWM (Light control)
SC-10LC/SC-20LC/SC-30LC
![]()
Solar Charger PWM
SC-45/SC-60
![]()
Solar Charger MPPT
SC-50 MPPT / SC-80 MPPT /
SC-80X MPPT
![]()
Solar Charger MPPT
SC-10 MPPT/SC-30 MPPT
![]()
Solar Charger PWM (IP67)
SC-05SM /SC-10SM /
SC-15SM / SC-20SM
![]()
SOLAR MODULE
OM6PV230
![]()
SOLAR LIGHT SYSTEM
MSS-10
![]()
Solar Power System
MSS-20 Super
![]()
solar power bank (MPPT)
12W Green Energy Kit
![]()
Solar Toys
Solar Carbon Fiber Car

HYBRID INVERTER - WALL MOUNT
SP 1200/2400/3600/5000/6000/11000-SW
OPTI-Solar HYBRID INVERTER, una versátil solución todo en uno, proporciona una potencia limpia de salida sinusoidal verdadera perfecta combinada con una corriente de carga de batería multifase que se puede seleccionar. El HYBRID INVERTER es adecuado para cualquier tipo de aplicación como, por ejemplo, aparatos de aire acondicionado o cualquier otro aparato doméstico, y su cargador inteligente carga automáticamente cualquier tipo de batería sin el riesgo de sobrecarga. Además, su diseño compacto y modular facilita y abarata la instalación. Este producto de alta calidad ofrece la mejor relación precio/rendimiento de la industria.
APLICACIONES
![]()
Aplicación Industrial, Residenciales, Comerciales
ESPECIFICACIONES
| MODEL | SP1200-SW(SR) | SP2400-SW(SR) | SP3600-SW(SR) | SP5000-SW | ||
| CAPACITY | VA / Watt | 1.2KVA/800W | 2.4KVA/1600W | 3.6KVA/2400W | 5KVA/4000W | |
| AC INPUT (FROM GRID) | Nominal Voltage | 120 Vac or 230 Vac | ||||
| Voltage Range | Acceptable Voltage Range | 60~135 Vac or 120~270 Vac | ||||
| Low Voltage Transfer | 60Vac ± 2% or 120Vac ± 3% | |||||
| Low Voltage Return | 65Vac ± 2% or 130Vac ± 3% | |||||
| High Voltage Transfer | 135VAC ± 2% or 270VAC ± 3% | |||||
| High Voltage Return | 130VAC ± 2% or 260VAC ± 3% | |||||
| Frequency | 50Hz or 60Hz | |||||
| DC INPUT (FROM ARRAY) | Nominal Voltage | 24V** | ||||
| Charger Voltage | 27.6V | |||||
| Solar Maximum Peak Voltage | 50V | |||||
| Start-up Voltage | 24V | |||||
| Polarity Protect | Yes | |||||
| Backflow Protect | Yes | |||||
| Maximum Charge Current | 40A | |||||
| OUTPUT | Voltage | 120 Vac (110V or 115Vac re-settable via LCD panel) 230 Vac (220V or 240Vac re-settable via LCD panel) |
||||
| Voltage Regulation(Battery Mode) | <3% RMS for entire battery voltage range | |||||
| Frequency Regulation | Line Mode | Synchronized to AC Main | ||||
| Battery Mode | 50Hz or 60Hz ±0.1Hz | |||||
| Power Factor | 0.67 | 0.8 | ||||
| Wave Form | Pure Sine Wave | |||||
| Overload Protection | Line Mode | >110%, then buzzer alarms and amber LED blinks continuously | ||||
| Battery Mode | 110%~150% for 30 sec ; >150% for 200ms | |||||
| Short Circuit Protection | Line Mode | Circuit Breaker | ||||
| Battery Mode | Electronic Circuit | |||||
| TRANSFER TIME | Typical | < 8 ms. | ||||
| BATTERY | Battery Voltage | 24Vdc | ||||
| Backup Time | Depends on system load and battery capacity (Base on the batteries connected) | |||||
| Selectable Charging Current | 10A / 20A / 30A | 16A / 32A / 50A | ||||
| DISPLAY | LCD | UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model | ||||
| LED | Normal (Green), Warning (Amber), Fault (Red) | |||||
| AUDIBLE ALARM | Battery Mode | Beeping every 4 seconds | ||||
| Low Battery | Beeping every second | |||||
| UPS Fault | Beeping continuously | |||||
| Overload | Beeping twice per second | |||||
| ENVIRONMENT | Operation Temperature | 0-40 °C ; 32-104 °F | ||||
| Relative Humidity | 0-95% non-condensing | |||||
| Audible Noise | Less than 55dBA (at 1M) | |||||
| PHYSICAL | SW: Wall-Mounted (Net/ Gross Weight) (Kgs) | 14 / 16 | 21 / 24.2 | 23 / 26 | 49.2 / 63 | |
| SR: Rack-Mounted (Net/ Gross Weight) (Kgs) | 15 / 17 | 19.4 / 21.4 | 25 / 27 | - | ||
| SW: Wall-Mounted (W*H*D) (mm) | 298 × 400 × 150 | 298 × 450 × 190 | 298 × 450 × 190 | 415 × 600 × 260 | ||
| SR: Rack-Mounted (W*H*D) (mm) | 440 × 322 × 132 | 440 × 392 × 132 | 440 × 392 × 132 | - | ||
| ACCESSORY | RS232 or SNMP | Optional | ||||
| MODEL | SP-6000-SW* | SP8000-SW | SP11000-SW | ||
| CAPACITY | VA / Watt | 6KVA/6000W | 8KVA/8000W | 11KVA/11000W | |
| AC INPUT (FROM GRID) | Nominal Voltage | 120 Vac or 230 Vac | 230 Vac | ||
| Voltage Range | Acceptable Voltage Range | 60~135 Vac or |
120~270 Vac | ||
| Low Voltage Transfer | 60Vac ± 2% or 120Vac ± 3% |
120Vac ± 2% | |||
| Low Voltage Return | 65Vac ± 2% or 130Vac ± 3% |
130Vac ± 2% | |||
| High Voltage Transfer | 135VAC ± 2% or 270VAC ± 3% |
270VAC ± 2% | |||
| High Voltage Return | 130VAC ± 2% or 260VAC ± 3% |
260VAC ± 2% | |||
| Frequency | 50Hz or 60Hz | ||||
| DC INPUT (FROM ARRAY) | Nominal Voltage | 48V | |||
| Charger Voltage | 55.2V | ||||
| Solar Maximum Peak Voltage | 100V | ||||
| Start-up Voltage | 44V | ||||
| Polarity Protect | Yes | ||||
| Backflow Protect | Yes | ||||
| Maximum Charge Current | 40A | ||||
| OUTPUT | Voltage | 120 Vac (110V or 115Vac re-settable via LCD panel) 230 Vac (220V or 240Vac re-settable via LCD panel) |
230 Vac (220 Vac or 240 Vac resettable via LCD panel) | ||
| Voltage Regulation(Battery Mode) | <3% RMS for entire battery voltage range | ||||
| Frequency Regulation | Line Mode | Synchronized to AC Main | |||
| Battery Mode | 50Hz or 60Hz ±0.1Hz | ||||
| Power Factor | 0.8 | 1.0 | |||
| Wave Form | Pure Sine Wave | ||||
| Overload Protection | Line Mode | >110%, then buzzer alarms and amber LED blinks continuously | |||
| Battery Mode | 110%~150% for 30 sec ; >150% for 200ms | ||||
| Short Circuit Protection | Line Mode | Circuit Breaker | |||
| Battery Mode | Electronic Circuit | ||||
| TRANSFER TIME | Typical | < 8 ms. | |||
| BATTERY | Battery Voltage | 48Vdc | |||
| Backup Time | Depends on system load and battery capacity (Base on the batteries connected) | ||||
| Selectable Charging Current | 20A / 40A / 60A | 28A / 56A / 85A | |||
| DISPLAY | LCD | UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model | |||
| LED | Normal (Green), Warning (Amber), Fault (Red) | ||||
| AUDIBLE ALARM | Battery Mode | Beeping every 4 seconds | |||
| Low Battery | Beeping every second | ||||
| UPS Fault | Beeping continuously | ||||
| Overload | Beeping twice per second | ||||
| ENVIRONMENT | Operation Temperature | 0-40 °C ; 32-104 °F | |||
| Relative Humidity | 0-95% non-condensing | ||||
| Audible Noise | Less than 55dBA (at 1M) | ||||
| PHYSICAL | SW: Wall-Mounted (Net/ Gross Weight) (Kgs) | 51.4 / 66.6 | 53.6 / 67.7 | 94.6 / 110.4 | |
| SW: Wall-Mounted (W*H*D) (mm) | 415 × 600 × 260 | 415 × 600 × 260 | 452 × 670 × 277 | ||
| ACCESSORY | RS232 or SNMP | Optional | |||
Specifications are subjected to change without prior notice.
* SP6000-SW could be upgraded to an off-grid inverter with an advanced CPU(optional A CPU).
** SP1200-SW(SR) 12V DC input is optional.
| El manual del usuario - Descargar el manual del usuario |
Catálogo - Descargar catálogo |
CERTIFICACIONES
![]()
![]() |
CE for SP Series |