Off Grid Solar Inverter with charger
SP6000-SW
![]()
HYBRID solar INVERTER with charger
SP1200-11000-SW
SP1200/2400/3600-SR
![]()
Hybrid / Off-Grid solar Inverter with AVR and charger
SP4000-AVR
![]()
High-Efficiency Hybrid / Off-Grid solar Inverter with charger
SP1000-5000 Efecto
![]()
True Hybrid Solar Inverter (on grid+off grid)
SP3000 Premium
![]()
All in one silent generator with AC utility and Solar charging
EP1200/2400/3600-SR
![]()
Solar Pumping System
Three Phase AC solar pumping inverter
DC Solar pumping inverter
![]()
Simulate sinewave Solar Inverter with charger
SP300Junior/SP600Junior
![]()
true sinewave inverter
INS-700/INS-1000
![]()
simulated sinewave inverter
IN-150S
![]()
Solar Charger PWM (Light control)
SC-10LC/SC-20LC/SC-30LC
![]()
Solar Charger PWM
SC-45/SC-60
![]()
Solar Charger MPPT
SC-50 MPPT / SC-80 MPPT /
SC-80X MPPT
![]()
Solar Charger MPPT
SC-10 MPPT/SC-30 MPPT
![]()
Solar Charger PWM (IP67)
SC-05SM /SC-10SM /
SC-15SM / SC-20SM
![]()
SOLAR MODULE
OM6PV230
![]()
SOLAR LIGHT SYSTEM
MSS-10
![]()
Solar Power System
MSS-20 Super
![]()
solar power bank (MPPT)
12W Green Energy Kit
![]()

HYBRID INVERTER - WALL MOUNT
SP 1200/2400/3600/5000/6000/8000/11000-SW
Die OPTI-Solar HYBRID INVERTER bieten eine leistungsstarke Rundumlösung, die unerreicht saubere Sinus-Ausgangsleistung in Kombination mit einstellbarem, mehrstufigem Ladestrom ermöglicht. Diese Wechselrichter eignen sich für mannigfache Anwendungen, beispielsweise zur Stromversorgung von Klimaanlagen und anderen Hausgeräten; ihre intelligente Ladeelektronik lädt sämtliche Arten von Akkumulatoren ohne Überladungsrisiko. Die kompakte und modulare Ausführung gewährleistet eine unproblematische, kostengünstige Installation. Dieses hochwertige Produkt bietet das beste Preis-Leistungs-Verhältnis der Branche.
ANWENDUGEN
![]()
Wohngebiet, Gewerbegebiet, und Industrieanwendung
TECNISCHE DATEN
| MODEL | SP1200-SW(SR) | SP2400-SW(SR) | SP3600-SW(SR) | SP5000-SW | ||
| CAPACITY | VA / Watt | 1.2KVA/800W | 2.4KVA/1600W | 3.6KVA/2400W | 5KVA/4000W | |
| AC INPUT (FROM GRID) | Nominal Voltage | 120 Vac or 230 Vac | ||||
| Voltage Range | Acceptable Voltage Range | 60~135 Vac or 120~270 Vac | ||||
| Low Voltage Transfer | 60Vac ± 2% or 120Vac ± 3% | |||||
| Low Voltage Return | 65Vac ± 2% or 130Vac ± 3% | |||||
| High Voltage Transfer | 135VAC ± 2% or 270VAC ± 3% | |||||
| High Voltage Return | 130VAC ± 2% or 260VAC ± 3% | |||||
| Frequency | 50Hz or 60Hz | |||||
| DC INPUT (FROM ARRAY) | Nominal Voltage | 24V** | ||||
| Charger Voltage | 27.6V | |||||
| Solar Maximum Peak Voltage | 50V | |||||
| Start-up Voltage | 24V | |||||
| Polarity Protect | Yes | |||||
| Backflow Protect | Yes | |||||
| Maximum Charge Current | 40A | |||||
| OUTPUT | Voltage | 120 Vac (110V or 115Vac re-settable via LCD panel) 230 Vac (220V or 240Vac re-settable via LCD panel) |
||||
| Voltage Regulation(Battery Mode) | <3% RMS for entire battery voltage range | |||||
| Frequency Regulation | Line Mode | Synchronized to AC Main | ||||
| Battery Mode | 50Hz or 60Hz ±0.1Hz | |||||
| Power Factor | 0.67 | 0.8 | ||||
| Wave Form | Pure Sine Wave | |||||
| Overload Protection | Line Mode | >110%, then buzzer alarms and amber LED blinks continuously | ||||
| Battery Mode | 110%~150% for 30 sec ; >150% for 200ms | |||||
| Short Circuit Protection | Line Mode | Circuit Breaker | ||||
| Battery Mode | Electronic Circuit | |||||
| TRANSFER TIME | Typical | < 8 ms. | ||||
| BATTERY | Battery Voltage | 24Vdc | ||||
| Backup Time | Depends on system load and battery capacity (Base on the batteries connected) | |||||
| Selectable Charging Current | 10A / 20A / 30A | 16A / 32A / 50A | ||||
| DISPLAY | LCD | UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model | ||||
| LED | Normal (Green), Warning (Amber), Fault (Red) | |||||
| AUDIBLE ALARM | Battery Mode | Beeping every 4 seconds | ||||
| Low Battery | Beeping every second | |||||
| UPS Fault | Beeping continuously | |||||
| Overload | Beeping twice per second | |||||
| ENVIRONMENT | Operation Temperature | 0-40 °C ; 32-104 °F | ||||
| Relative Humidity | 0-95% non-condensing | |||||
| Audible Noise | Less than 55dBA (at 1M) | |||||
| PHYSICAL | SW: Wall-Mounted (Net/ Gross Weight) (Kgs) | 14 / 16 | 21 / 24.2 | 23 / 26 | 49.2 / 63 | |
| SR: Rack-Mounted (Net/ Gross Weight) (Kgs) | 15 / 17 | 19.4 / 21.4 | 25 / 27 | - | ||
| SW: Wall-Mounted (W*H*D) (mm) | 298 × 400 × 150 | 298 × 450 × 190 | 298 × 450 × 190 | 415 × 600 × 260 | ||
| SR: Rack-Mounted (W*H*D) (mm) | 440 × 322 × 132 | 440 × 392 × 132 | 440 × 392 × 132 | - | ||
| ACCESSORY | RS232 or SNMP | Optional | ||||
| MODEL | SP-6000-SW* | SP8000-SW | SP11000-SW | ||
| CAPACITY | VA / Watt | 6KVA/6000W | 8KVA/8000W | 11KVA/11000W | |
| AC INPUT (FROM GRID) | Nominal Voltage | 120 Vac or 230 Vac | 230 Vac | ||
| Voltage Range | Acceptable Voltage Range | 60~135 Vac or |
120~270 Vac | ||
| Low Voltage Transfer | 60Vac ± 2% or 120Vac ± 3% |
120Vac ± 2% | |||
| Low Voltage Return | 65Vac ± 2% or 130Vac ± 3% |
130Vac ± 2% | |||
| High Voltage Transfer | 135VAC ± 2% or 270VAC ± 3% |
270VAC ± 2% | |||
| High Voltage Return | 130VAC ± 2% or 260VAC ± 3% |
260VAC ± 2% | |||
| Frequency | 50Hz or 60Hz | ||||
| DC INPUT (FROM ARRAY) | Nominal Voltage | 48V | |||
| Charger Voltage | 55.2V | ||||
| Solar Maximum Peak Voltage | 100V | ||||
| Start-up Voltage | 44V | ||||
| Polarity Protect | Yes | ||||
| Backflow Protect | Yes | ||||
| Maximum Charge Current | 40A | ||||
| OUTPUT | Voltage | 120 Vac (110V or 115Vac re-settable via LCD panel) 230 Vac (220V or 240Vac re-settable via LCD panel) |
230 Vac (220 Vac or 240 Vac resettable via LCD panel) | ||
| Voltage Regulation(Battery Mode) | <3% RMS for entire battery voltage range | ||||
| Frequency Regulation | Line Mode | Synchronized to AC Main | |||
| Battery Mode | 50Hz or 60Hz ±0.1Hz | ||||
| Power Factor | 0.8 | 1.0 | |||
| Wave Form | Pure Sine Wave | ||||
| Overload Protection | Line Mode | >110%, then buzzer alarms and amber LED blinks continuously | |||
| Battery Mode | 110%~150% for 30 sec ; >150% for 200ms | ||||
| Short Circuit Protection | Line Mode | Circuit Breaker | |||
| Battery Mode | Electronic Circuit | ||||
| TRANSFER TIME | Typical | < 8 ms. | |||
| BATTERY | Battery Voltage | 48Vdc | |||
| Backup Time | Depends on system load and battery capacity (Base on the batteries connected) | ||||
| Selectable Charging Current | 20A / 40A / 60A | 28A / 56A / 85A | |||
| DISPLAY | LCD | UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model | |||
| LED | Normal (Green), Warning (Amber), Fault (Red) | ||||
| AUDIBLE ALARM | Battery Mode | Beeping every 4 seconds | |||
| Low Battery | Beeping every second | ||||
| UPS Fault | Beeping continuously | ||||
| Overload | Beeping twice per second | ||||
| ENVIRONMENT | Operation Temperature | 0-40 °C ; 32-104 °F | |||
| Relative Humidity | 0-95% non-condensing | ||||
| Audible Noise | Less than 55dBA (at 1M) | ||||
| PHYSICAL | SW: Wall-Mounted (Net/ Gross Weight) (Kgs) | 51.4 / 66.6 | 53.6 / 67.7 | 94.6 / 110.4 | |
| SW: Wall-Mounted (W*H*D) (mm) | 415 × 600 × 260 | 415 × 600 × 260 | 452 × 670 × 277 | ||
| ACCESSORY | RS232 or SNMP | Optional | |||
Specifications are subjected to change without prior notice.
* SP6000-SW could be upgraded to an off-grid inverter with an advanced CPU(optional A CPU).
** SP1200-SW(SR) 12V DC input is optional.
DOWNLOAD
| Bedienungsanleitung - Bedienungsanleitung herunterladen |
Katalog - Katalog herunterladen |
ZERTIFIZIERUNGEN
![]()
![]() |
CE for SP Series |