Off Grid Solar Inverter with charger
SP6000-SW

HYBRID solar INVERTER with charger
SP1200-11000-SW
SP1200/2400/3600-SR

Hybrid / Off-Grid solar Inverter with AVR and charger
SP4000-AVR

High-Efficiency Hybrid / Off-Grid solar Inverter with charger
SP1000-5000 Efecto

True Hybrid Solar Inverter (on grid+off grid)
SP3000 Premium

All in one silent generator with AC utility and Solar charging
EP1200/2400/3600-SR


Solar Pumping System
Three Phase AC solar pumping inverter
DC Solar pumping inverter

Simulate sinewave Solar Inverter with charger
SP300Junior/SP600Junior

true sinewave inverter
INS-700/INS-1000

simulated sinewave inverter
IN-150S

Solar Charger PWM (Light control)
SC-10LC/SC-20LC/SC-30LC

Solar Charger PWM
SC-45/SC-60


Solar Charger MPPT
SC-50 MPPT / SC-80 MPPT /
SC-80X MPPT

Solar Charger MPPT
SC-10 MPPT/SC-30 MPPT

Solar Charger PWM (IP67)
SC-05SM /SC-10SM /
SC-15SM / SC-20SM

SOLAR MODULE
OM6PV230

SOLAR LIGHT SYSTEM
MSS-10


Solar Power System
MSS-20 Super


solar power bank (MPPT)
12W Green Energy Kit

solar lantern
SP1
SP2

HYBRID INVERTER - WALL MOUNT
SP 1200/2400/3600/5000/6000/8000/11000-SW

Die OPTI-Solar HYBRID INVERTER bieten eine leistungsstarke Rundumlösung, die unerreicht saubere Sinus-Ausgangsleistung in Kombination mit einstellbarem, mehrstufigem Ladestrom ermöglicht. Diese Wechselrichter eignen sich für mannigfache Anwendungen, beispielsweise zur Stromversorgung von Klimaanlagen und anderen Hausgeräten; ihre intelligente Ladeelektronik lädt sämtliche Arten von Akkumulatoren ohne Überladungsrisiko. Die kompakte und modulare Ausführung gewährleistet eine unproblematische, kostengünstige Installation. Dieses hochwertige Produkt bietet das beste Preis-Leistungs-Verhältnis der Branche.

MERKMALE

* Multiprozessorbasis
* Arbeitet mit linearen und nichtlinearen Lasten
* Leistungsfähige Ladeelektronik, auch geeignet für Akkumulatoren mit 600 Ah und mehr
* 24-Stunden-Wechselrichterbetrieb
* Abnehmbares LCD-Bedienfeld
* Parameter-Voreinstellung
* 3U-/19-Zoll-Rack- oder Wandmontage
* Für harte Einsatzbedingungen geeignet
* Geringe Wärmeabgabe im Langzeitbetrieb
* Weniger als 3 % harmonische Verzerrungen
* AC/DC Priority Switchable CPU


ANWENDUGEN

Wohngebiet, Gewerbegebiet, und Industrieanwendung

 

TECNISCHE DATEN

MODEL SP1200-SW(SR) SP2400-SW(SR) SP3600-SW(SR) SP5000-SW
CAPACITY VA / Watt 1.2KVA/800W 2.4KVA/1600W 3.6KVA/2400W 5KVA/4000W
AC INPUT (FROM GRID) Nominal Voltage 120 Vac or 230 Vac
Voltage Range Acceptable Voltage Range 60~135 Vac or 120~270 Vac
Low Voltage Transfer 60Vac ± 2% or 120Vac ± 3%
Low Voltage Return 65Vac ± 2% or 130Vac ± 3%
High Voltage Transfer 135VAC ± 2% or 270VAC ± 3%
High Voltage Return 130VAC ± 2% or 260VAC ± 3%
Frequency 50Hz or 60Hz
DC INPUT (FROM ARRAY) Nominal Voltage 24V**
Charger Voltage 27.6V
Solar Maximum Peak Voltage 50V
Start-up Voltage 24V
Polarity Protect Yes
Backflow Protect Yes
Maximum Charge Current 40A
OUTPUT Voltage 120 Vac (110V or 115Vac re-settable via LCD panel)
230 Vac (220V or 240Vac re-settable via LCD panel)
Voltage Regulation(Battery Mode) <3% RMS for entire battery voltage range
Frequency Regulation Line Mode Synchronized to AC Main
Battery Mode 50Hz or 60Hz ±0.1Hz
Power Factor 0.67 0.8
Wave Form Pure Sine Wave
Overload Protection Line Mode >110%, then buzzer alarms and amber LED blinks continuously
Battery Mode 110%~150% for 30 sec ; >150% for 200ms
Short Circuit Protection Line Mode Circuit Breaker
Battery Mode Electronic Circuit
TRANSFER TIME Typical < 8 ms.
BATTERY Battery Voltage 24Vdc
Backup Time Depends on system load and battery capacity (Base on the batteries connected)
Selectable Charging Current 10A / 20A / 30A 16A / 32A / 50A
DISPLAY LCD UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model
LED Normal (Green), Warning (Amber), Fault (Red)
AUDIBLE ALARM Battery Mode Beeping every 4 seconds
Low Battery Beeping every second
UPS Fault Beeping continuously
Overload Beeping twice per second
ENVIRONMENT Operation Temperature 0-40 °C ; 32-104 °F
Relative Humidity 0-95% non-condensing
Audible Noise Less than 55dBA (at 1M)
PHYSICAL SW: Wall-Mounted (Net/ Gross Weight) (Kgs) 14 / 16 21 / 24.2 23 / 26 49.2 / 63
SR: Rack-Mounted (Net/ Gross Weight) (Kgs) 15 / 17 19.4 / 21.4 25 / 27 -
SW: Wall-Mounted (W*H*D) (mm) 298 × 400 × 150 298 × 450 × 190 298 × 450 × 190 415 × 600 × 260
SR: Rack-Mounted (W*H*D) (mm) 440 × 322 × 132 440 × 392 × 132 440 × 392 × 132 -
ACCESSORY RS232 or SNMP Optional

 

MODEL SP-6000-SW* SP8000-SW SP11000-SW
CAPACITY VA / Watt 6KVA/6000W 8KVA/8000W 11KVA/11000W
AC INPUT (FROM GRID) Nominal Voltage 120 Vac or 230 Vac 230 Vac
Voltage Range Acceptable Voltage Range

60~135 Vac or
120~270 Vac

120~270 Vac
Low Voltage Transfer 60Vac ± 2% or
120Vac ± 3%
120Vac ± 2%
Low Voltage Return 65Vac ± 2% or
130Vac ± 3%
130Vac ± 2%
High Voltage Transfer 135VAC ± 2% or
270VAC ± 3%
270VAC ± 2%
High Voltage Return 130VAC ± 2% or
260VAC ± 3%
260VAC ± 2%
Frequency 50Hz or 60Hz
DC INPUT (FROM ARRAY) Nominal Voltage 48V
Charger Voltage 55.2V
Solar Maximum Peak Voltage 100V
Start-up Voltage 44V
Polarity Protect Yes
Backflow Protect Yes
Maximum Charge Current 40A
OUTPUT Voltage 120 Vac (110V or 115Vac re-settable via LCD panel)
230 Vac (220V or 240Vac re-settable via LCD panel)
230 Vac (220 Vac or 240 Vac resettable via LCD panel)
Voltage Regulation(Battery Mode) <3% RMS for entire battery voltage range
Frequency Regulation Line Mode Synchronized to AC Main
Battery Mode 50Hz or 60Hz ±0.1Hz
Power Factor 0.8 1.0
Wave Form Pure Sine Wave
Overload Protection Line Mode >110%, then buzzer alarms and amber LED blinks continuously
Battery Mode 110%~150% for 30 sec ; >150% for 200ms
Short Circuit Protection Line Mode Circuit Breaker
Battery Mode Electronic Circuit
TRANSFER TIME Typical < 8 ms.
BATTERY Battery Voltage 48Vdc
Backup Time Depends on system load and battery capacity (Base on the batteries connected)
Selectable Charging Current 20A / 40A / 60A 28A / 56A / 85A
DISPLAY LCD UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model
LED Normal (Green), Warning (Amber), Fault (Red)
AUDIBLE ALARM Battery Mode Beeping every 4 seconds
Low Battery Beeping every second
UPS Fault Beeping continuously
Overload Beeping twice per second
ENVIRONMENT Operation Temperature 0-40 °C ; 32-104 °F
Relative Humidity 0-95% non-condensing
Audible Noise Less than 55dBA (at 1M)
PHYSICAL SW: Wall-Mounted (Net/ Gross Weight) (Kgs) 51.4 / 66.6 53.6 / 67.7 94.6 / 110.4
SW: Wall-Mounted (W*H*D) (mm) 415 × 600 × 260 415 × 600 × 260 452 × 670 × 277
ACCESSORY RS232 or SNMP Optional

Specifications are subjected to change without prior notice.
* SP6000-SW could be upgraded to an off-grid inverter with an advanced CPU(optional A CPU).
** SP1200-SW(SR) 12V DC input is optional.

 

DOWNLOAD

Bedienungsanleitung
- Bedienungsanleitung herunterladen
Katalog
- Katalog herunterladen

 

ZERTIFIZIERUNGEN

CE
CE for SP Series