HYBRID solar INVERTER
with charger
SP1200-11000-SW
SP1200-3600-SR

Hybrid / Off-Grid solar Inverter with AVR and charger
SP4000-AVR

High-Efficiency Hybrid /
Off-Grid solar Inverter
with charger (PWM)

SP1000-5000 Efecto

High-Efficiency Hybrid /
Off-Grid solar Inverter
with charger (MPPT)

SP2000-5000 Brilliant

Grid-Tie Solar Inverter (MPPT)
SP3000 Vigor/SP5000 Vigor

True Hybrid Solar Inverter with Energy Storage
(on grid+off grid)
SP2000 Premium - SP3000 Premium

3 Phase Solar inverter with Energy Storage(on grid+off grid)
SP10K Premium

Energy Storage System
EP1200/2400/3600-SR

off grid Simulated sinewave Solar Inverter with charger
SP300Junior-SP5000Junior

true sinewave inverter
INS-700-INS-1000

Solar Charger MPPT
SC-3KW MPPT

Solar Charger MPPT
SC-10/15/20MPPT

Solar Charger MPPT
SC-600W MPPT

Solar Charger PWM (IP67)
SC-05/10/15/20SM
SC-05/10/15/20SM-Z

Solar Charger PWM with LCD
SC-20MAX-SC40MAX

SOLAR MODULE
OM6PV250

HYBRID INVERTER - WALL MOUNT
SP 1200/2400/3600/5000/6000/8000-SW/SP11000-SW

The OPTI-Solar HYBRID INVERTER, a powerful all-in-one solution, delivers unsurpassed clean true sine wave output power combined with a selectable multistage battery charging current. The Hybrid/Off-Grid Inverter is suitable for any kind of applications such as air conditioner or any other home appliances, and its intelligent charger automatically charges any types of batteries without the risk of overcharge, while its compact & modular design makes installation easier and more cost efficient. This high quality product offers the best price/performance ratio in the industry.

FEATURES

• Multiple Microprocessor design
• Compatible with both linear and non-linear load
• Stronger charger to support batteries up to 600AH
• Controllable & Removable panel with LCD
• DC start and automatic self-diagnostic function
• Designed to operate under harsh environment
• Low heat dissipation in long time operation
• 3U 19" Rack-Mounted Design or Wall-Mounted Design
• Pre-settable Parameters
• 24 hours operation on the inverter
• THD less than 3%


APPLICATIONS

Residential, Commercial, and Industrial application

 

SPECIFICATIONS

MODEL SP1200-SW(SR) SP2400-SW(SR) SP3600-SW(SR) SP5000-SW
CAPACITY VA / Watt 1.2KVA/800W 2.4KVA/1600W 3.6KVA/2400W 5KVA/4000W
AC INPUT (FROM GRID) Nominal Voltage 120 Vac or 230 Vac
Voltage Range Acceptable Voltage Range 60~135 Vac or 120~270 Vac
Low Voltage Transfer 60Vac ± 2% or 120Vac ± 3%
Low Voltage Return 65Vac ± 2% or 130Vac ± 3%
High Voltage Transfer 135VAC ± 2% or 270VAC ± 3%
High Voltage Return 130VAC ± 2% or 260VAC ± 3%
Frequency 50Hz or 60Hz
DC INPUT (FROM ARRAY) Nominal Voltage 24V**
Charger Voltage 27.6V
Solar Maximum Peak Voltage (VOC) 50V
Start-up Voltage 24V
Polarity Protect Yes
Backflow Protect Yes
Maximum Charge Current (ISC) 40A
OUTPUT Voltage 120 Vac (110V or 115Vac re-settable via LCD panel)
230 Vac (220V or 240Vac re-settable via LCD panel)
Voltage Regulation(Battery Mode) <3% RMS for entire battery voltage range
Frequency Regulation Line Mode Synchronized to AC Main
Battery Mode 50Hz or 60Hz ±0.1Hz
Power Factor 0.67 0.8
Wave Form Pure Sine Wave
Overload Protection Line Mode >110%, then buzzer alarms and amber LED blinks continuously
Battery Mode 110%~150% for 30 sec ; >150% for 200ms
Short Circuit Protection Line Mode Circuit Breaker
Battery Mode Electronic Circuit
TRANSFER TIME Typical < 8 ms.
BATTERY Battery Voltage 24Vdc
Backup Time Depends on system load and battery capacity (Base on the batteries connected)
Selectable Charging Current 10A / 20A / 30A 16A / 32A / 50A
DISPLAY LCD UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model
LED Normal (Green), Warning (Amber), Fault (Red)
AUDIBLE ALARM Battery Mode Beeping every 4 seconds
Low Battery Beeping every second
UPS Fault Beeping continuously
Overload Beeping twice per second
ENVIRONMENT Operation Temperature 0-40 °C ; 32-104 °F
Relative Humidity 0-95% non-condensing
Audible Noise Less than 55dBA (at 1M)
PHYSICAL SW: Wall-Mounted (Net/ Gross Weight) (Kgs) 14 / 16 21 / 24.2 23 / 26 49.2 / 63
SR: Rack-Mounted (Net/ Gross Weight) (Kgs) 15 / 17 19.4 / 21.4 25 / 27 -
SW: Wall-Mounted (W*H*D) (mm) 298 × 400 × 150 298 × 450 × 190 298 × 450 × 190 415 × 600 × 260
SR: Rack-Mounted (W*H*D) (mm) 440 × 322 × 132 440 × 392 × 132 440 × 392 × 132 -
ACCESSORY RS232 or SNMP Optional

 

MODEL SP-6000-SW* SP8000-SW SP11000-SW
CAPACITY VA / Watt 6KVA/6000W 8KVA/8000W 11KVA/11000W
AC INPUT (FROM GRID) Nominal Voltage 120 Vac or 230 Vac 230 Vac
Voltage Range Acceptable Voltage Range

60~135 Vac or
120~270 Vac

120~270 Vac
Low Voltage Transfer 60Vac ± 2% or
120Vac ± 3%
120Vac ± 2%
Low Voltage Return 65Vac ± 2% or
130Vac ± 3%
130Vac ± 2%
High Voltage Transfer 135VAC ± 2% or
270VAC ± 3%
270VAC ± 2%
High Voltage Return 130VAC ± 2% or
260VAC ± 3%
260VAC ± 2%
Frequency 50Hz or 60Hz
DC INPUT (FROM ARRAY) Nominal Voltage 48V
Charger Voltage 55.2V
Solar Maximum Peak Voltage (VOC) 100V
Start-up Voltage 44V
Polarity Protect Yes
Backflow Protect Yes
Maximum Charge Current (ISC) 40A
OUTPUT Voltage 120 Vac (110V or 115Vac re-settable via LCD panel)
230 Vac (220V or 240Vac re-settable via LCD panel)
230 Vac (220 Vac or 240 Vac resettable via LCD panel)
Voltage Regulation(Battery Mode) <3% RMS for entire battery voltage range
Frequency Regulation Line Mode Synchronized to AC Main
Battery Mode 50Hz or 60Hz ±0.1Hz
Power Factor 1.0
Wave Form Pure Sine Wave
Overload Protection Line Mode >110%, then buzzer alarms and amber LED blinks continuously
Battery Mode 110%~150% for 30 sec ; >150% for 200ms
Short Circuit Protection Line Mode Circuit Breaker
Battery Mode Electronic Circuit
TRANSFER TIME Typical < 8 ms.
BATTERY Battery Voltage 48Vdc
Backup Time Depends on system load and battery capacity (Base on the batteries connected)
Selectable Charging Current 20A / 40A / 60A 28A / 56A / 85A
DISPLAY LCD UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model
LED Normal (Green), Warning (Amber), Fault (Red)
AUDIBLE ALARM Battery Mode Beeping every 4 seconds
Low Battery Beeping every second
UPS Fault Beeping continuously
Overload Beeping twice per second
ENVIRONMENT Operation Temperature 0-40 °C ; 32-104 °F
Relative Humidity 0-95% non-condensing
Audible Noise Less than 55dBA (at 1M)
PHYSICAL SW: Wall-Mounted (Net/ Gross Weight) (Kgs) 51.4 / 66.6 53.6 / 67.7 94.6 / 110.4
SW: Wall-Mounted (W*H*D) (mm) 415 × 600 × 260 415 × 600 × 260 452 × 670 × 277
ACCESSORY RS232 or SNMP Optional

Specification are subject to change without notice.
* SP6000-SW could be upgraded to an off-grid inverter with an advanced CPU (optional A-CPU).
** SP1200-SW(SR) 12V DC input is optional.

 

DOWNLOAD

User Manual
- Download User Manual
Catalogue
- Download Catalogue

 

CERTIFICATIONS

CE
CE for SP Series