The SOLAR HYBRID INVERTER, a powerful all-in-one solution, delivers unsurpassed clean true sine wave output power and combines this with a selectable multistage battery charging current. Applicable for any kinds of loads such as air conditioner, home appliances, and intelligent charger automatically charges any types of batteries without the risk of overcharge. The compact & modular design makes utility interactive installations easier and more cost effective. It is a high quality product that offers the best price/performance ratio in the industry.
Features
* Multiple Microprocessor design base
* Compatible with both linear and non-linear load
* Stronger charger to support batteries of 600AH and up
* 24 hours operation on the inverter
* Controllable & Removable panel with LCD
* Parameter Pre-settable
* DC start and automatic self-diagnostic function
* 3u 19” Rack-mount design or Wall-mount design
* Designed to operate under harsh environment
* Low heat dissipation in long time operation
* THD less than 3%
* High efficiency design to save electricity
Specifications
|
SP1200-SR |
SP2400-SR |
SP3600-SR |
|||||||
|
Capacity |
VA / Watt |
1.2KVA / 800W |
2.4KVA / 1600W |
3.6KVA / 2400W |
|||||
|
(from Grid) |
Nominal Voltage |
230Vac; 120Vac |
|||||||
|
Voltage Range |
Acceptable Voltage Range |
120-270Vac ; 90-135Vac |
|||||||
|
Frequency |
50Hz / 60Hz ( 45Hz - 70Hz) |
||||||||
|
Line Low Transfer |
120VAC ± 2% ; 90VAC ± 3% |
||||||||
|
Line Low Return |
130VAC ± 2% ; 95VAC ± 3% |
||||||||
|
Line High Transfer |
270VAC ± 2% ; 135VAC ± 3% |
||||||||
|
Line High Return |
260VAC ± 2% ; 130VAC ± 3% |
||||||||
|
(from Array) |
Nominal Voltage |
12V |
24V |
24V |
|||||
|
Charge Voltage |
13.8V |
27.6V |
27.6V |
||||||
|
Solar Maximum Peak Voltage |
25V |
50V |
50V |
||||||
|
Start-up Voltage |
12V |
24V |
24V |
||||||
|
Polarity Protect |
Yes |
Yes |
Yes |
||||||
|
Backflow Protect |
Yes |
Yes |
Yes |
||||||
|
Maximum Charge Current |
50A |
||||||||
|
Output |
Voltage |
230Vac (220V or 240VAC re-settable via LCD panel); |
|||||||
|
Voltage Regulation (Batt. Mode) |
< 3% RMS for entire battery voltage range |
||||||||
|
Frequency |
50Hz or 60Hz |
||||||||
|
Frequency Regulation (Batt. Mode) |
± 0.1Hz |
||||||||
|
Power Factor |
0.67 |
||||||||
|
Waveform |
Pure Sinewave |
||||||||
|
Efficiency |
> 75% |
> 80% |
|||||||
|
Overload Protection |
Line Mode |
Circuit Breaker |
|||||||
|
Battery Mode |
110% ~ 150% for 30 sec. , >150% for 200ms |
||||||||
|
Transfer Time |
Typical |
< 8 ms. |
|||||||
|
Battery |
Battery Voltage |
12Vdc |
24Vdc |
24Vdc |
|||||
|
Backup Time |
Depends on System Load and Battery Capacity |
||||||||
|
Max. Charging Current (5 steps selectable) |
40A |
50A |
|||||||
|
Display |
LCD |
UPS status, I/P&O/P Voltage Frequency, Load%, |
|||||||
|
Battery Voltage & %, Charge current, Temperature, Model |
|||||||||
|
LED |
Normal (Green), Warning (Yellow), Fault (Red) |
||||||||
|
Audible Alarm |
Battery Mode |
Beeping every 4 seconds |
|||||||
|
Low Battery |
Beeping every second |
||||||||
|
UPS Fault |
Beeping Continuously |
||||||||
|
Overload |
Beeping twice per second |
||||||||
|
Environment |
Operation Temperature |
0-40 degree C; 32-104 degree F |
|||||||
|
Relative Humidity |
0-95% non-condensing |
||||||||
|
Physical |
Audible Noise |
Less than 55dBA (at 1M) |
|||||||
|
14/ 16 |
21/ 24.2 |
23/ 26 |
|||||||
|
Net/ Gross Weigh (Kgs) Rack |
15/ 17 |
19.4/ 21.4 |
25/ 27 |
||||||
|
(W x H x D)mm Wall Mounted |
298 x 150 x 400 |
298 x 190 x 450 |
298 x 190 x 450 |
||||||
|
(W x H x D)mm Rack Mount |
440 x 132 x 322 |
440 x 132 x 392 |
440 x 132 x 392 |
||||||
|
Accessory |
RS232 or SNMP |
Optional |
|||||||
|
|
|
|
|
|
|
|
|
|
|