HYBRID INVERTER - WALL MOUNT SP5000-SW/6000-SW/8000-SW
Strong DC/AC transformer design with higher efficiency, enjoy the stability and reliability all the time.
FEATURES • Compatible with both linear and non-linear load
• Controllable & Removable panel with LCD
• DC start and automatic self-diagnostic function
• Designed to operate under harsh environment
• Heat dissipation design
• 3U 19" Rack-Mounted Design or Wall-Mounted Design
• Pre-settable Parameters
• 24hrs operation under inverter mode
• THD less than 3%
• DC/AC transformer design
APPLICATION DIAGRAM
APPLICATIONS Residential, Commercial, and Industrial application
SPECIFICATIONS
MODEL
SP5000-SW
SP6000-SW
SP8000-SW
CAPACITY
VA / Watt
5KVA/4000W
6KVA/6000W
8KVA/8000W
AC INPUT (FROM ARRAY)
Nominal Voltage
120 Vac or 230 Vac
230 Vac
Voltage Range
Acceptable Voltage Range
60~135 Vac or 120~270 Vac
120~270 Vac
Low Voltage Transfer
60 Vac ±2% ; 120 Vac ±3%
120 Vac ±2%
Low Voltage Return
65 Vac ±2% ; 130 Vac ±3%
130 Vac ±2%
High Voltage Transfer
135 Vac ±% ; 270 Vac ±3%
270 Vac ±2%
High Voltage Return
130 Vac ±2% ; 260 Vac ±3%
260 Vac ±2%
Frequency
50Hz or 60Hz
DC INPUT (FROM ARRAY)
Nominal Voltage
24V
48V
Charger Voltage
27.6V
55.2V
Solar Maxmum Peak Voltage
50V
100V
Start-up Voltage
24V
44V
Polarity Protect
Yes
Backflow Protect
Yes
Maximum Charge Current
40A
OUTPUT
Voltage
110/115/120Vac
220/230/240Vac
220/230/240Vac
Voltage Regulation(Battery Mode)
<3% RMS for entire battery voltage range
Frequency Regulation
Line Mode
Synchronized to AC Main
Battery Mode
50Hz or 60Hz ±0.1Hz
Power Factor
0.8
1
Wave Form
Pure Sine Wave
Overload Protection
Line Mode
>110%, then buzzer alarms and amber LED blinks continuously
Battery Mode
110%~150% for 30 sec ; >150% for 200ms
Short Circuit Protection
Line Mode
Circuit Breaker
Battery Mode
Electronic Circuit
TRANSFER TIME
Typical
< 8 ms.
Battery Voltage
24Vdc
48Vdc
Backup Time
Depends on system load and battery capacity (Base on the batteries connected)
Selectable Charging Current
Yes
DISPLAY
LCD
UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model
LED
Normal (Green), Warning (Amber), Fault (Red)
AUDIBLE ALARM
Battery Mode
Beeping every 4 seconds
Low Battery
Beeping every second
UPS Fault
Beeping continuously
Overload
Beeping twice per second
ENVIRONMENT
Operation Temperature
0-40°C ; 32-104°F
Relative Humidity
0-95% non-condensing
Audible Noise
Less than 55dBA (at 1M)
PHYSICAL
Weight (Net / Gross Weight)
49.2kgs / 63kgs
51.4kgs / 66.6kgs
53.6kgs / 67.7kgs
Dimensions (W×H×D)
415×600×260mm
415×600×260mm
415×600×260mm
ACCESSORY
RS232 or SNMP
Optional
Specification are subject to change without notice.