GRID-TIED INVERTER SPECIFICATIONS (U.S.)
Model |
GT 1500 |
GT 2000 |
GT 3000 |
GT 4000 |
Input Data |
||||
Maximum Input Power (W) |
1875 |
2500 |
3750 |
5000 |
Nominal Input Power (W) |
1575 |
2160 |
3159 |
4230 |
Maximum input voltage (V) |
450 |
|||
Nominal DC voltage (V) |
360 - 400 |
|||
Working voltage range |
100V +/-5% ~ 450 - 5% +0% |
|||
MPPT voltage range |
150 - 450 +/-5% |
|||
System start-up voltage (V) |
100 +/-5% |
|||
Full rating working voltage |
250V to 450V |
|||
Max. input current |
10ADC |
10ADC |
20ADC |
20ADC |
Shutdown voltage |
80V typical |
|||
DC voltage ripple |
< 10% |
|||
DC insulation resistance |
> 8M ohm |
|||
GFDI Switch |
On / Off 30A |
|||
DC Terminal |
Terminal block |
|||
Output Data |
||||
Nominal output power |
1500W |
2000W |
3000W *7 |
4000W |
Maximum continuous output power (20°C) |
1650W |
2200W |
3300W *8 |
4400W |
Operational Voltage range *1 |
190V ~ 224V @ 208Vac |
|||
Operational Normal Voltage |
208Vac / 240Vac |
|||
Operational Frequency range (Hz) |
59.3 ~ 60.3 for 60Hz*3 |
|||
Nominal output Frequency |
60Hz |
|||
Max. input short circuit current |
<30A |
|||
Max. input source back feed current to input source (A) |
0 |
|||
Max. output over current protection |
< 14.0A |
< 18.8A |
< 28.1A |
< 37.5A |
Synchronization in rush current |
10.6A* |
14.1A* |
21.2A* |
28.3A* |
9.3A |
12.2A |
18.4A |
24.6A |
|
Nominal output current |
7.2A* |
9.6A* |
14.4A* |
19.2A* |
6.3A |
8.3A |
12.5A |
16.7A |
|
O/P current distortion *4 |
THD<5%, each harmonics <3% |
|||
Power Factor |
> 0.99% |
Accuracy |
≤ 2% |
Utility interconnection voltage and frequency |
< 0.16 sec |
DC current injection |
< 0.5% of rated inverter output current |
|||
General Data |
||||
Internal power consumption |
< 7W |
|||
Standby power (at night) |
< 0.1W |
|||
Minimum Conversion Efficiency (DC/AC) |
> 90%, Under input voltage> 210V, load >20% |
|||
Maximum Conversion Efficiency (DC/AC) *5 |
> 95.0% |
> 95.5% |
> 96.0% |
> 96.0% |
CEC Efficiency |
> 94.5% |
> 95.0% |
> 95.5% |
> 95.5% |
GFDI threshold *6 |
See ground fault current detection |
Max. output fault current and duration |
< 100A |
|
Ground current detection frequency |
0~700Hz |
|||
Protection degree |
NEMA 3R (rain proof) |
|||
Operation temperature |
-25 to 45˚C |
-25 to 45˚C |
Storage temperature |
-25°C to 70°C |
Humidity |
0 to 95%, non-condensing |
|||
Heat Dissipation |
Convection |
|||
Acoustic noise level |
< 40dB, A-weighted, frequency up to 20kHz |
|||
Altitude |
Up to 3000m without power derating, 5∘C dearted for each additional 500m |
|||
Physical: WxDxH(mm) |
352x450x133 |
352x450x133 |
352x450x143 |
550x450x143 |
Physical: Weight(kg) |
15 |
15 |
16 |
22 |
Shipping: WxDxH(mm) |
470x580x290 |
470x580x290 |
470x580x290 |
670x580x290 |
Shipping: Weight(kg) |
17 |
17 |
18 |
24 |
Certifications |
Approvals |
ETL+CSA |
-- |
||
The relation of input DC voltage and output power is shown in figure. Once input V is less than 250V, the relation of I/PV and load % is : LOAD% = 0.4xV1
![]() |
Explanation 1.VDE0126-1-1, it is -20%/ +15% |
|